FITNESS FOR SERVICE USING BSI PD6493 & API 579

Performed several finite element analyses to check the structural integrity of three heat exchangers. The exchangers were evaluated for the existing wall surface cracks and an estimated life for the cracks was determined. The study considered steady state operations as well as transient start up conditions using finite element analysis. The resulting maximum stress intensities from the steady state operating conditions and the transient start up conditions were compared to ASME Section VIII, Division 2 Code, using ASME Section VIII Division 1 allowable stresses. For the crack evaluation/analysis, the BSI PD6493 & API 579 were used.